Follow the instructions below to update your ScreenLogic2™ system
- For all systems, first update the Protocol Adapter, as explained in Step 1
- Once the Protocol Adapter is up to date, then perform the subsequent updates depending on the interfaces you have installed in your system
Step 1: Update your Protocol Adapter
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Once the download is complete, double-click the downloaded file
- Locate and select the protocol adapter in the list, then click Start
- The update process will complete in a few minutes
- If any errors occur during the update:
- Close the update tool
- Restart the update program
- If a second attempt to update fails, then contact Pentair Technical Support for more information
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Once the download is complete, double-click the downloaded file
- Locate and select the protocol adapter in the list, then click Start
- The update process will complete in a few minutes
- If any errors occur during the update:
- Close the update tool
- Restart the update program
- If a second attempt to update fails, then contact Pentair Technical Support for more information
Step 2: Update your Interface(s)
- Download ScreenLogic setup program for Windows XP, Vista, and 7
- For PCs: Click Here to download the latest version.
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
NOTE: For Windows users, there will be a new icon shortcut called "ScreenLogic Connect" on your desktop. The first time you run this program, RIGHT click on the icon and choose "Run as Administrator". This is only required the first time you run this application. You can subsequently start this program by double clicking on the "ScreenLogic Connect" icon.
- Download ScreenLogic Connect for Mac Computers (Mac OS versions 10.5, 10.6, 10.7, Intel CPUs only)
- For Macs: Click Here to start the download
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Once the download is complete, Open the DMG file and drag it into the Applications folder.
- To update the In-Wall Touch Screen you must update three files stored on the device. The recommended method described here uses a USB flash drive to transfer the files. Access to the USB port on the In-Wall Touch Screen requires temporarily removing the device from the wall, but does not require disconnecting cables.
NOTE: Some USB flash drives are not compatible with the In-Wall Touch Screen. If you have trouble, try a different USB drive.
- Download the zip file containing the updates for the In-Wall Touch Screen
- Click Here to start the download
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Extract the three files (right-click the zip file, select Extract All)
- Copy the files from the extracted folder to the USB flash drive
- If ScreenLogic is running on the device, bring up the keyboard and type CTRL-Q to close
- Carefully remove the bezel from the front, then remove the four screws that hold the device to the back-box
- Pull the device out to access the USB port (next to the network cable)
- Plug the USB flash drive into one of the USB ports
- Double-click My Computer: if the USB drive is supported, you will see a Hard Disk folder
- Double-click the Hard Disk folder to access the files on the USB drive
- Select all three files, and then click Edit, Copy
- Browse back to the FlashStorage2 folder, then click Edit, Paste
- Once the files have been copied, close File Explorer
- Remove the USB drive and replace the In-Wall Touch Screen
- Please ensure that the protocol adapter has been updated before proceeding with these steps.
- To update the In-Wall Touch Screen you must update three files stored on the device. The recommended method described here requires an active Ethernet connection to the Internet.
- You will need to download 3 files, one at a time, to the NandFlash directory on the Profile 700 touch screen using the built-in Internet Explorer browser.
- If ScreenLogic is running on the device, bring up the keyboard and type CTRL-Q to close. Close all other programs.
- Launch Internet Explorer browser from the Desktop
- Enter this URL into the browser for the 1st file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IB/CRYSTALPAD.exe
- Enter this URL into the browser for the 2nd file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IB/HelveticaLTStd-BoldCond.ttf
- Enter this URL into the browser for the 3rd file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IB/MINIPAD.exe
- Choose to overwrite if prompted.
- After the 3rd file has been downloaded, double tap on the MINIPAD.EXE file. This will launch the new ScreenLogic interface.
- Please ensure that the protocol adapter has been updated before proceeding with these steps.
- To update the In-Wall Touch Screen you must update three files stored on the device. The recommended method described here requires an active Ethernet connection to the Internet.
- You will need to download 3 files, one at a time, to the NandFlash directory on the TS7 touch screen using the built-in Internet Explorer browser.
- If ScreenLogic is running on the device, bring up the keyboard and type CTRL-Q to close. Close all other programs.
- Launch Internet Explorer browser from the Desktop
- Enter this URL into the browser for the 1st file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IC/CRYSTALPAD.exe
- Enter this URL into the browser for the 2nd file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IC/HelveticaLTStd-BoldCond.ttf
- Enter this URL into the browser for the 3rd file and choose to save it to the NandFlash directory on the in-wall:
http://www.pentairpool.com/downloads/Tablet-ARMV4IC/MINIPAD.exe
- Choose to overwrite if prompted.
- After the 3rd file has been downloaded, double tap on the MINIPAD.EXE file. This will launch the new ScreenLogic interface.
- To update the Wireless Tablet you must update three files stored on the device. The recommended method described here uses a USB flash drive to transfer the files.
NOTE: Some USB flash drives are not compatible with the Wireless Tablet. If you have trouble, try a different USB drive.
- Download the appropriate zip file containing the updates for your Wireless Tablet
- Click Here to start the download
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Extract the three files (right-click the zip file, select Extract All)
- Copy the files from the extracted folder to the USB flash drive
- If ScreenLogic is running on the device, bring up the keyboard and type CTRL-Q to close
- Plug the USB flash drive into the USB port on the tablet
- Double-click My Computer: if the USB drive is supported, you will see a Hard Disk folder
- Double-click the Hard Disk folder to access the files on the USB drive
- Select all three files, and then click Edit, Copy
- Browse back to the FlashStorage2 (DT366), the Internal Storage (DT375) or the IPSM (Kube) folder, and then click Edit, Paste
- Once the files have been copied, close File Explorer
- Remove the USB drive
- To update the Wireless Tablet you must update three files stored on the device. The recommended method described here uses a USB flash drive to transfer the files.
NOTE: Some USB flash drives are not compatible with the Wireless Tablet. If you have trouble, try a different USB drive.
- Download the appropriate zip file containing the updates for your Wireless Tablet
- Click Here to start the download
- If your browser shows an information bar, click and then select "Download file"
- When prompted, click Desktop to save the file on your desktop
- Extract the three files (right-click the zip file, select Extract All)
- Copy the files from the extracted folder to the USB flash drive
- If ScreenLogic is running on the device, bring up the keyboard and type CTRL-Q to close
- Plug the USB flash drive into the USB port on the tablet
- Double-click My Computer: if the USB drive is supported, you will see a Hard Disk folder
- Double-click the Hard Disk folder to access the files on the USB drive
- Select all three files, and then click Edit, Copy
- Browse back to the FlashStorage2 (DT366), the Internal Storage (DT375) or the IPSM (Kube) folder, and then click Edit, Paste
- Once the files have been copied, close File Explorer
- Remove the USB drive
Note: The Remote Control & Monitoring software is meant for Service Personnel and Pool Builders. Homeowners should use ScreenLogic Connect software listed under Step 2 above.
Build 649 released 10/1/11. All existing users should update to this version.
Pentair Remote Control & Monitoring software (available for PC and Mac)
- For PCs: Click here to download the latest version. This will update your existing version retaining all customer data.
- For Macs: Click here to download the latest version. This will update your existing version retaining all customer data.
Note: Please perform a backup of your data (Under the Customers drop down menu) before upgrading
If you do not own the ScreenLogic2, click here for archived downloads.
|